您好,登錄后才能下訂單哦!
1: 6509 主引擎 SYSTEM亮紅燈
2: 6509 機箱背面線路集成板亮紅燈
二、設備硬件指示燈層面分析:
思科官方針對主引擎上,system亮燈的幾種情況的說明:
Green—All chassis environmental monitors are reporting OK.
Orange—The power supply has failed or the power supply fan hasfailed.
Red—Incompatible power supplies are installed.(電源異常)
–The redundant clock has failed.(冗余時鐘異常)
–One VTT1 module has failed or the VTT module temperature minorthreshold has been exceeded2 .(一塊VTT模塊異常,或者VTT模塊溫度異常)
–Two VTT modules fail or the VTT module temperature major thresholdhas been exceeded3.(兩塊VTT模塊異常,或者溫度異常)
–The temperature of the supervisor engine major threshold has beenexceeded(引擎溫度異常)
三、設備系統告警層面分析:
6509有如下告警:
environmental alarms:
system minor alarm on operating VTT count(raised 18w1d ago)
system minor alarm on VTT 2 OK (raised18w1d ago)
四、設備系統層面分析:
查看6509硬件狀態,有如下狀態描述:
VTT 2:
VTT 2 OK: not OK
VTT 2 outlettemperature: 29C
說明VTT2 模塊系統檢測狀態不正常
VTT:電壓終端模塊,用于Catalyst交換總線。如果沒有安裝冗余Supervisor引擎,并且VTT模塊處于輕微或者嚴重溫度過高狀態,則系統就會關機。在背板上有三個電壓調節器(VTT)。如果一個VTT模塊出現故障,則就會出現輕微告警。如果兩個出現故障,則就會出現重大告警,正確措施就是關閉系統
五、結論:
該6509機箱背板中,VTT2 電壓終端模塊出現異常,現在系統中仍有2塊VTT模塊正常工作,如果再出現一塊VTT電壓終端模塊異常,將會使系統嚴重告警,如果情況嚴重可能導致整臺6509停止工作。
一臺6509最大只能承受2塊VTT模塊異常。